List of parameters
Parameters
1-335
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the status for checking and monitoring flying restart states in the V/f control mode.
Description:
Displays the status for checking and monitoring flying restart states in the vector control mode.
Note:
Bits 0..9: Used by the control in internal sequences during the flying restart.
Depending on the machine type (p0300), the number of active bits differs.
Bits 10..15: Are used to monitor the flying restart sequence.
For PEM, only bits 10, 11 and 15 are supported.
r1204.0...13
CO/BO: Flying restart, V/f control status / FlyRestrt Uf stat
VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Current impressed
Yes
No
-
01
No current flow
Yes
No
-
02
Voltage input
Yes
No
-
03
Voltage reduced
Yes
No
-
04
Start ramp-function generator
Yes
No
-
05
Wait for execution
Yes
No
-
06
Slope filter act
Yes
No
-
07
Positive gradient
Yes
No
-
08
Current < thresh
Yes
No
-
09
Current minimum
Yes
No
-
10
Search in the positive direction
Yes
No
-
11
Stop after positive direction
Yes
No
-
12
Stop after negative direction
Yes
No
-
13
No result
Yes
No
-
r1205.0...15
CO/BO: Flying restart, vector control status / FlyRestrtVectStat
VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Save the angle of the speed adaptation cir-
cuit
Yes
No
-
01
Set speed adaptation circuit gain to 0
Yes
No
-
02
Enable Isd channel
Yes
No
-
03
Speed control switched-in
Yes
No
-
04
Quadrature arm switched-in
Yes
No
-
05
Special transformation active
Yes
No
-
06
Set I comp speed adaptation circuit to 0
Yes
No
-
07
Current control on
Yes
No
-
08
Isd_set = 0 A
Yes
No
-
09
Reserved
Yes
No
-
10
Search in the positive direction
Yes
No
-
11
Search Started
Yes
No
-
12
Current impressed
Yes
No
-
13
Search interrupted
Yes
No
-
14
Deviation of the speed adaptation circuit = 0 Yes
No
-
15
Speed control activated
Yes