Parameters
Parameters for data sets
1-1084
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
1.3.4
Parameters for Motor Data Sets (MDS)
The following list contains the motor-data-set-dependent parameters.
Product: SINAMICS S, Version: 2503100, Language: eng
p0131[0...n]
Motor component number / Mot comp_no
p0300[0...n]
Motor type selection / Mot type selection
p0301[0...n]
Motor code number selection / Mot code No. sel
r0302[0...n]
Motor code number of motor with DRIVE-CLiQ / Motor code Mot DLQ
r0303[0...n]
Motor status word from motor with DRIVE-CLiQ / Motor ZSW Drv-CliQ
p0304[0...n]
Rated motor voltage / Mot V_rated
p0305[0...n]
Rated motor current / Mot I_rated
p0306[0...n]
Number of motors connected in parallel / Motor qty
p0307[0...n]
Rated motor power / Mot P_rated
p0308[0...n]
Rated motor power factor / Mot cos_phi_rated
p0309[0...n]
Rated motor efficiency / Mot eta_rated
p0310[0...n]
Rated motor frequency / Mot f_rated
p0311[0...n]
Rated motor speed / Mot n_rated
p0311[0...n]
Rated motor velocity / Mot v_rated
p0312[0...n]
Rated motor torque / Mot M_rated
p0312[0...n]
Rated motor force / Mot F_rated
r0313[0...n]
Motor pole pair number, actual (or calculated) / Mot PolePairNo act
p0314[0...n]
Motor pole pair number / Mot pole pair No.
p0315[0...n]
Motor pole pair width / MotPolePair width
p0316[0...n]
Motor torque constant / Mot kT
p0316[0...n]
Motor force constant / Mot kT
p0317[0...n]
Motor voltage constant / Mot kE
p0318[0...n]
Motor stall current / Mot I_standstill
p0319[0...n]
Motor stall torque / Mot M_standstill
p0319[0...n]
Motor stall force / Mot F_standstill
p0320[0...n]
Motor rated magnetization current/short-circuit current / Mot I_mag_rated
p0322[0...n]
Maximum motor speed / Mot n_max
p0322[0...n]
Motor maximum velocity / Mot v_max
p0323[0...n]
Maximum motor current / Mot I_max
p0325[0...n]
Motor pole position identification current, 1st phase / Mot PolID I 1st ph
p0326[0...n]
Motor stall torque correction factor / Mot M_stall_corr
p0326[0...n]
Motor stall force correction factor / Mot F_stall_corr
p0327[0...n]
Optimum motor load angle / Mot phi_load opt
p0328[0...n]
Motor reluctance torque constant / Mot kT_reluctance
p0328[0...n]
Motor reluctance force constant / Mot kT_reluctance
p0329[0...n]
Motor pole position identification current / Mot PolID current
r0330[0...n]
Rated motor slip / Mot slip_rated
r0331[0...n]
Motor magnetizing current/short-circuit current actual / Mot I_mag_ratedAct
r0332[0...n]
Rated motor power factor / Mot cos_phi_rated
r0333[0...n]
Rated motor torque / Mot M_rated
r0334[0...n]
Motor-torque constant, actual / Mot kT act
r0334[0...n]
Motor force constant, actual / Mot kT act
Note:
References: /FH1/
SINAMICS S120 Function Manual Drive Functions
Section "Data sets"