Test Functions
596
88000 Series
OH - SONET/SDH
For OC-12: The M1 byte located in the STS-1 #7 indicates BIP
violations.
For OC-48: The M1 byte located in the STS-1 #7 indicates BIP
violations.
For OC-192: Either the M1 byte located in the STS-1 #7, or the
combination of the M0 and M1 bytes indicates BIP violations (refer
to
REI-L Computation Method
For
M1 Only
computation method:
M1, bits 234 5678
Indicates
000 0000
0 BIP violation
000 0001
1 BIP violation
:
:
110 0000
96 BIP violations
110 0001 to
1111 1111
0 BIP violation
M1
Indicates
0000 0000
0 BIP violation
0000 0001
1 BIP violation
:
:
1111 1111
255 BIP violations
M1
Indicates
0000 0000
0 BIP violation
0000 0001
1 BIP violation
:
:
1111 1111
255 BIP violations