Test Setup - Test Applications
72
88000 Series
Carrier Ethernet OAM
Carrier Ethernet OAM
The Carrier Ethernet OAM test application supports the following tests:
Ethernet OAM (S-OAM)
,
MPLS-TP OAM
, and
Link OAM
.
Ethernet OAM and MPLS TP OAM
The Ethernet Service OAM tests are divided into two main categories:
Performance Monitoring measures parameters such as frame delay,
frame loss, and synthetic loss (Y.1731/MEF).
Connectivity Fault Management provides the capability for detecting,
verifying, and isolating connectivity failure (Y.1731/802.1ag/MEF).
Typical Ethernet OAM and MPLS TP OAM test applications:
Supported Interfaces/Rates: 10M to 10G LAN/WAN.
MIP
EXFO Module
Peer MEP
Local MEP
MIP
EXFO Module
Local MEP
EXFO Module
Smart Loopback with
S-OAM Responder enabled.