Test Setup - Test Configurator, Timer, and System
Power Blazer
257
RFC 2544 - Subtests
Accuracy
is the accuracy measurement in percentage of the line rate
(
%
),
Mbit/s
, or in
Gbit/s
. The accuracy is not based on the configured
Maximum Rate
but on the Ethernet line rate. The accepted values are
as follows:
Acceptable Errors
represents the number of acceptable errors for the
test:
0
(default) to
10
.
Validations
represents the number of times the result should be
validated:
1
(default) to
50
times.
Interface
Speed
Max. Rate
%
Mbit/s
Gbit/s
10 Mbit/s
0.1 to 10.0
(default 1.0)
0.01 to 1.0
(default 0.10)
Not Applicable
100 Mbit/s 0.1 to 10.0
(default 1.0)
0.1 to 10.0
(default 1.0)
Not Applicable
1000 Mbit/s 0.1 to 10.0
(default 1.0)
1 to 100.0
(default 10)
0.001 to 0.100
(default 0.010)
10G LAN
0.1 to 10.0
(default 1.0)
10.0 to 1000.0
(default 100)
0.01 to 1.00
(default 0.10)
10G WAN
0.1 to 10.0
(default 1.0)
10.0 to 1000.0
(default 100.00)
0.01 to 1.00
(default 0.1)
40G 0.1
to
10.0
(default 1.0)
40.0 to 4000.0
(default 400.0)
0.04 to 4.00
(default 0.40)
100G 0.1
to
10.0
(default 1.0)
100.0 to 10000.0
(default 1000.0)
0.10 to 10.00
(default 1.0000)
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......