Test Setup - Test Configurator, Timer, and System
Power Blazer
267
S-OAM and MPLS-TP OAM
S-OAM and MPLS-TP OAM
From the test menu, tap
Setup
,
Test Configurator
, and the
S-OAM (Y.1731/802.1ag/MEF
) or
MPLS-TP OAM (G.8113.1)
test block.
OAM Mode
Allows the selection of the OAM mode.
OAM Type
OAM Mode
S-OAM Y.1731
(default) supports both Connectivity Fault Management and
Performance Monitoring which includes all S-OAM functions supported by
this module.
802.1ag
supports Connectivity Fault Management including only the
Continuity Check, Loopback, Link Trace, and RDI functions.
MEF
supports both Connectivity Fault Management and Performance
Monitoring which includes all S-OAM functions supported by this module.
MPLS-TP OAM
G.8113.1 (default) supports both Connectivity Fault Management and
Performance Monitoring which includes all MPLS-TP OAM functions
supported by this module.