Test Setup - Test Configurator, Timer, and System
Power Blazer
179
FTFL/PT and PT
PT / Global PT
Note:
Global PT, available with Muti-Channel OTN, indicates that the PT settings
apply to all channels.
Note:
Changing the payload type (PT) does not alter the signal structure; it only
modifies the OH value that is generated.
Overwrite
1
check box when selected generates the defined PT.
Payload Type
and
Code
Generated
: Allows the selection of the payload signal type to be
generated either by selecting the payload type from the list or by
entering its code in hexadecimal (
00
to
FF
).
Expected
: Allows selecting the expected payload signal type.
Note:
Codes not listed in the table are reserved for future standardization
(Reserved For International Standardization).
1. Only available with Through Intrusive topology and applies only to the ODU top layer.
Payload type
Hex Code
MSB
1234
LSB
5678
Reserved for International Standardization
a
00
0000
0000
Experimental mapping
01
0000
0001
Asynchronous CBR mapping
02
0000
0010
Bit Synchronous CBR mapping
03
0000
0011
ATM mapping
04
0000
0100
GFP mapping
05
0000
0101
Virtual Concatenation Signal
06
0000
0110
PCS Codeword Transparent Ethernet
07
0000
0111
FC-1200 into ODU2e
08
0000
1000
GFP mapping into extended OPU2
09
0000
1001
OC-3/STM-1 into ODU0
0A
0000
1010
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......