Test Setup - Test Configurator, Timer, and System
302
88000 Series
Signal - Signal Configuration (OTN)
Signal - Signal Configuration (OTN)
Note:
The following signal configuration parameters are available from the
interface block.
From the
Test
menu, tap
Setup
,
Test Configurator
, the interface block,
and on the
Signal
tab.
OTU4
,
OTU3
,
OTU3e1
,
OTU3e2
,
OTU2
,
OTU2f
,
OTU1f
,
OTU2e
,
OTU1e
, or
OTU1
Note:
At least one of the two check boxes,
FEC
or
Scrambler
, must be selected in
order to prevent potential alarms caused by a lack of bit transition on the
optical signal. For example to disable
FEC
, first select the
Scrambler
check
box then clear the
FEC
check box.
FEC
check box, when selected (default), enables the FEC in TX/RX
and allows detecting, reporting, and correcting up to 8 symbol
errors (Correctable) per codeword. If there are over 8 symbol
errors detected, they are reported as uncorrectable errors.
Scrambler
check box, when selected (default), provides enough
“0” and “1” transitions on the optical signal for clock recovery.
Note:
When the
Scrambler
check box is cleared, the receiver circuitry is forced to
operate in a condition which is outside of the specified OTN operating
conditions, potentially causing alarms/errors. This configuration can be
used for special analysis in a lab environment.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......