Test Setup - Test Configurator, Timer, and System
Power Blazer
145
Cable Test
Cable Test
From the
Test
menu, tap
Setup
,
Test Configurator
, and the test block.
Global Options
Wiring Standard
is the pin-to-pair assignment corresponding to the
UTP cable used:
T568A
(default) or
T568B
.
Length Unit
is the unit used for cable length and distance to fault
results:
Meter
(default) or
Feet
.
PoE
check box when selected (cleared by default) allows verifying that
the Power Sourcing Equipment (PSE) is capable to deliver appropriate
power (PoE) to the Powered Device (PD). The PoE test is performed
after the cable test is executed confirming that the cable is ready to
carry data and power: either the Wire Map test reported
No fault
,
Straight pair
,
Crossed Pair
, or
Noise (link up)
. Only available on
8870/8880.