Test Results
Power Blazer
457
SDT (Multi-Channel OTN)
SDT (Multi-Channel OTN)
From the
Test
menu, tap
Results
and the
SDT
tab.
Note:
The SDT tab is only available when
Disruption Monitoring
is enabled
(refer to
Service Disruption is the time during which there is a disruption of service
due to the absence of traffic or to the detection of defects per channel.
Channels with Disruption
indicates the number of channels with
service disruption.
Channels Monitored
indicates the number of channels monitored.
Channels Above Threshold
, available when pass/fail verdict is
enabled, indicates the number of channels with a disruption time
above the defined threshold.
Longest Disruption
indicates the duration of the longest measured
disruption time and the channel number on which it occurred. The
Pass/Fail verdict when enabled, is displayed next to duration value.
Last Disruption
indicates the duration of the last measured disruption
time and the channel number on witch it occurred.
SDT Threshold (ms)
, available when pass/fail verdict is enabled,
allows entering the SDT threshold value that will be used to declare the
pass/fail verdict:
0.001
to
299999.999 ms
(default is
50
ms).
The following statistics are presented per channel:
Channel
indicates the channel number.
Longest (ms)
indicates the longest measured disruption time.
Shortest (ms)
indicates the shortest measured disruption time.
Last (ms)
indicates the duration of the last measured disruption time.
Average (ms)
indicates the average duration of all measured
disruption times.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......