Test Setup - Test Configurator, Timer, and System
Power Blazer
269
S-OAM and MPLS-TP OAM
Pass/Fail Verdict
Pass/Fail Verdict
check box when selected (default) enables the use of the
pass/fail verdict. A global fail verdict is declared when any of the following
condition is met:
Link Down
alarm,
Loss Continuity
alarm, or any fail
verdict for
Frame Delay
,
Frame Loss
,
Synthetic Loss
(Only applicable to
Ethernet OAM),
Frame Delay Failure
,
Frame Loss Failure
,
Synthetic Loss
Failure
(Only applicable to Ethernet OAM),
Loopback Failure
, or
Test
Failure
.
Thresholds
Available with G.8113.1, Y.1731 and MEF OAM Modes when Pass/Fail verdict
is enabled. The verdict is PASS when the measured value is lower or equal
to the threshold value.
Frame Delay Threshold (ms)
allows setting the threshold value of
frame delay:
0.001
to
8000
ms (default is
50
ms).
Frame Loss Threshold (%)
allows setting the threshold value of frame
loss:
0.001
to
100
% (default is
10
%).
Synthetic Loss Threshold (%
), available with Ethernet OAM (Y.1731
and MEF), allows setting the threshold value of Synthetic Loss:
0.001
to
100
% (default is
10
%).
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......