Test Functions
556
88000 Series
FDL - Bit-Oriented Message
FDL - Bit-Oriented Message
Allows setting and configuring the Bit-Oriented Messages (BOM) of the
Extended Super-Frame (ESF).
Note:
FDL is only available for DS1 interface with ESF framing. For Dual RX test,
FDL is only available for the DS1 TX/RX port 1.
From the
Test
menu, tap
Functions
,
FDL
, and the
Bit-Oriented Message
tab.
Generated Messages
Priority
Codeword
: The Bit-Oriented Message codewords are priority
messages sent over the Data-Link. These messages are mostly used for
networking operation and maintenance. A Bit-Oriented Message
consists of 8 consecutive ones followed by a byte starting and ending
by zeros.
Injects
generates the selected codeword priority message.
Command/Response
Amount
allows the selection of the number of message to be
generated. Choices are
1
to
15
. The default value is
10
.
Inject
manually generates the selected amount of messages.
Codeword
Pattern
RAI
00000000 11111111
Loopback Retention and Acknowledge
00101010 11111111
RAI-CI
00111110 11111111
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......