Test Functions
Power Blazer
587
OH - OTN
Row 2
RES
, columns 1-2, ODU OH: The two Reserved (RES) bytes are
configurable from
00
(default for each byte) to
FF
.
PM & TCM
, column 3, ODU OH: The Path Monitoring and Tandem
Connection Monitoring byte is configurable from
00
(default) to
FF
.
TCM ACT
, column 4, ODU OH: The Tandem Connection Monitoring
Activation is configurable from
00
(default) to
FF
.
TCM6
/
TCM5
/
TCM4
, column 5-13, ODU OH: The Tandem Connection
Monitoring overhead contains the following bytes.
The first TCMi byte contains the TTI multiframe byte and is only
configurable from
The second TCMi byte contains the BIP-8 byte and is automatically
generated for each frame. This byte is not configurable.
The third TCMi byte contains the following sub-fields. This byte is
configurable from
00
to
FF
. The default value is
00
when TCMi is
disabled, and 01 when enabled.
FTFL
, column 14, ODU OH: The Fault Type Fault Location multiframe
byte is only configurable from
JC5
or
RES
1
JC5
, column 15, OPU OH: Bits 1-3 set to all-0s, and bits 4-8 are
controlled by GMP function. This byte is not configurable.
RES
, column 15, OPU OH: The Reserved (RES) byte is configurable
from
00
(default) to
FF
.
Bit 1-4
Bit 5
Bit 6-8
BEI/BIAE
BDI
STAT
1. Depending on the test MUX/Mapping.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......