Test Functions
Power Blazer
567
Filters
Filters
Allows gathering statistics according to the programmed filters. Filters
provide the capability to analyze a specific stream’s behavior in order to
monitor a single protocol’s behavior, perform SLA verification, or precisely
troubleshoot unwanted behavior. Up to 10 filters having up to four
operands each can be defined and enabled.
From the
Test
menu, tap
Functions
, and the
Filters
tab.
P1 and P2 Buttons
The
P1
and
P2
buttons, available with
Dual Port
topology, allow
respectively displaying results for port #1 (
P1
) or port #2 (
P2
).
Filters
Allows the selection of the filter number (1 to 10). The filter criteria, if
defined, will be displayed. A filter used (enabled) for data capture will not
be configurable and the message
Filter in use for data capture
is
displayed.
Enable
Once the filter is configured, select the
Enable
check box to enable the
current filter. However, if the filter configuration contains errors, it will not
be possible to enable it. A filter can be enabled or disabled even when the
test is running. It is not possible to modify or disable a filter that is already in
use for capture until either another filter or
Interface
(see
on page 571) is assigned to capture.
Enabled Time
Indicates the time during which the filter is enabled.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......