Test Results
Power Blazer
453
S-OAM and MPLS-TP OAM
Invalid Payload
indicates the count of received LBR frames having
either a TLV type different than the one transmitted, Bit error or wrong
data value detected in the data payload of a Data TLV, Bit error, Pattern
Loss, or Pattern Type mismatch of a Test TLV.
Successful
indicates the count of received LBR frames having no
errors.
Failed
indicates the count of LBR frames declared as invalid.
Test
Status
displays the status of the test function (refer to page 511).
TX TST
indicates the count of transmitted TST frames.
RX TST
indicates the count of valid TST frames received. A valid frame
for S-OAM has its source MAC address matching the Peer MEP MAC
address; destination MAC address matching either the unit port Unicast
MAC address or a Multicast class 1 address
1
; and VLANs matching the
unit port VLANs. A valid frame for MPLS-TP OAM has its destination
MAC address matching either the unit MAC address, FF:FF:FF:FF:FF:FF,
or 01:00:5E:90:00:00; VLANs matching the unit port VLANs; and MPLS
Labels matching the local MPLS Label Stack configuration.
Invalid TST
indicates the count of TST frames received from the peer
MEP with incorrect MEG/MD level.
Invalid Payload
indicates the count of received TST frames having
either an unsupported pattern type, or bit error / pattern loss detected
in the payload.
Successful
indicates the count of received TST frames having no
errors.
Failed
indicates the count of TST frames declared as invalid.
1. Refer to
Unicast/Multicast Addresses for Ethernet OAM
on page 757 for more information.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......