Test Setup - Test Configurator, Timer, and System
332
88000 Series
Traces (OTN)
Traces (OTN)
For OTN BERT and OTN-SONET/SDH BERT: From the
Test
menu tap
Setup
,
Test Configurator
, tap on the interface block, and on the
Traces
tab.
For Multi-Channel OTN: From the
Test
menu, tap
Setup
,
Test
Configurator
, tap on either:
the interface block, and on the
Traces
tab to configure the higher ODU
layer.
the test block (
ODU Channels
), and on the
Traces
tab to configure the
lower ODU layer. Traces settings apply to all channels unless otherwise
indicated.
OTUx, ODUx, and TCM Buttons
Tap on either OTUx or an ODUx button. For ODUx when TCM is enabled
(see Modify TCM on page 306), tap on a TCMx button to select a TCM level.
TCM is not available with Multi-Channel OTN.
SM/PM/TCM TTI Traces
Note:
The TTI Traces are configurable for SM (OTUx), PM (ODUx), and TCM
(ODUx when TCM is enabled; see
Modify TCM
on page 306).
Overwrite
check box when selected generates the defined messages.
Only available with
Through Intrusive
topology and applies only to the
OTU and ODU top layers.
Generated Message
Allows editing the SAPI, DAPI and Operator Specific messages to be
generated.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......