Test Functions
562
88000 Series
FDL - Performance Report Message
Performance Information
table, available when the
Report Content
button is selected, reports the time t0, t0-1, t0-2, and t0-3 for each PRM.
Time
T0
represents the valid PRM message received in the last second of
measurement (bytes 5 and 6).
T0-1
represents the message one PRM ago (bytes 7 and 8).
T0-2
represents the message two PRM ago (bytes 9 and 10).
T0-3
represents the message three PRM ago (bytes 11 and 12).
PRM
G3
: 5 < CRC Error Event
10
LV
: Line Code Violation Event
1
G4
: 10 < CRC Error Event
100
U1
: Under study for synchronization
U2
: Under study for synchronization
G5
: 100 < CRC Error Event
319
SL
: Controlled Slip Event
1
G6
: CRC Error Event
320
FE
: Frame Sync. Bit Error Event
1
SE
: Severely-Errored Framing Event
1
LB
: Payload Loopback Activated
G1
: CRC Error Event = 1
R
: Reserved
G2
: 1 < CRC Error Event
5
Nm
and
Nl
: One-second report modulo 4 counter.