Test Functions
544
88000 Series
40/100G/400G Advanced - CFP4/CFP8/QSFP Control
CFP4/CFP8/QSFP MDIO/I2C Access Interface
MDIO/I2C - Bulk Read
Page Select
, available for QSFP I2C, allows selecting the I2C
address page:
0x00
(default) to
0xFF
.
MDIO/I2C Start Address
allows selecting the MDIO/I2C start
address:
0x0000
(default) to
0xFFFF
(MDIO)/
0x00FF
(I2C).
MDIO/I2C End Address
allows selecting the MDIO
/I2C
end
address:
0x0000
to
0xFFFF
; default is
0x00FF
.
Bulk Read
button reads and displays the data based on the
specified MDIO range (MDIO/I2C Start Address to MDIO/I2C End
Address).
Save to CSV
button allows saving the read MDIO/I2C’s addresses
and data to a CSV file.
Note:
The bulk read size is limited to 1024 addresses.
MDIO/I2C - Read/Write
MDIO/I2C Address
allows selecting the MDIO/I2C address:
0x0000
(default) to
0xFFFF
(MDIO)/
0x00FF
(I2C).
MDIO/I2C Data
allows either selecting (write) or reading the
MDIO/I2C data:
0x0000
(default) to
0xFFFF
(MDIO)/
0x00FF
(I2C).
Read
button reads the data of the specified
MDIO/I2C Address
.
Write
button writes the specified
MDIO/I2C DATA
value to the
specified
MDIO/I2C Address
.
CFP4/CFP8 TX Status
Indicates the transceiver transmission status for each optical lane.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......