Test Functions
580
88000 Series
OH - GFP-F/GFP-T
OH - GFP-F/GFP-T
Note:
Available with OTN BERT test application with
1GbE
(GFP-T),
10GbE
(GFP-F), or
Ethernet (flex/GFP-F)
client.
From the
Test
menu, tap
Functions
,
OH
tab, and
GFP-F/GFP-T
sub tab.
Core Header
PLI
and
cHEC
are not configurable.
Type Header
The following settings are available for
Client Data
and
Client
Management
frame types
.
PTI
(Payload Type Identifier) allows overwriting the Payload Type
Identifier.
PFI
(Payload Frame Check Sequence Identifier) allows overwriting
the Payload FCS Indicator.
PTI
Description
000
Client Data Frame
100
Client Management Frame
001, 010, 011, 101, 110, and 111
Reserved
PFI
Description
0
FCS Absent
1
FCS Present
Summary of Contents for Power Blazer 88000 Series