Test Setup - Test Configurator, Timer, and System
212
88000 Series
MAC/IP/UDP
MPLS
Note:
MPLS is only available when the MPLS Label is enabled; refer to
Label
allows the selection of the MPLS TX labels:
0
to
1048575
(default
is
16
). Refer to for the list of MPLS labels.
COS
allows the selection of the Class Of Service.
0 (000 - Low)
(default)
1 (001 - Low)
2 (010 - Low)
3 (011 - Low)
4 (100 - High)
5 (101 - High)
6 (110 - High)
7 (111 - High)
TTL
allows the selection of the
Time to Live
value:
0 to 255
(default
is
128
).
S-OAM
Note:
S-OAM
is only available with EtherSAM when the
S-OAM
check box is
selected; refer to
MEG/MD Level
allows the selection of the Maintenance Entity Group
Level / Maintenance Domain Level:
0
to
7
(default).