Test Results
396
88000 Series
Alarms/Errors Overview
C-FDI
(Client Signal Fail - Forward Defect Indication)
RX
: A CSF frame is received with CSF type equal to
001
.The alarm is
cleared when no CSF (C-FDI) frames are received during an interval
equal to 3.5 times the CSF transmission period indicated in the last
received CSF (C-FDI) frame, or when a CSF frame is received with
Client Defect Clear Indication (C-DCI) information (CSF Type 011).
TX
: Generates a CSF frame with CSF type equal to
001
.
C-RDI
(Client Signal Fail - Remote Defect Indication)
RX
: A CSF frame is received with CSF type equal to
010
. The alarm is
cleared when no CSF (C-RDI) frames are received during an interval
equal to 3.5 times the CSF transmission period indicated in the last
received CSF (C-RDI) frame, or when a CSF frame is received with
Client Defect Clear Indication (C-DCI) information (CSF Type 011).
TX
: Generates a CSF frame with CSF type equal to
010
.
C-DCI
(Client Signal Fail - Defect Clear Indication)
TX
: Generates a CSF frame with CSF type equal to
011
.