Test Setup - Test Configurator, Timer, and System
Power Blazer
143
BERT and Unframed BERT
Note:
The Service Disruption Time measurement supports a parent defect
approach where the SDT measurement is triggered when the selected
defect or a higher defect in the signal structure hierarchy is detected. For
example, if Bit Error is selected, an OPU AIS error will trigger an SDT event.
No Defect Time (ms)
represents the period without any defects before
stopping SDT measurement:
0.005 ms
to
2000 ms
(default is
300 ms
).
Disruption Monitoring
check box when selected (disabled by
default) enables the disruption time measurements. However, the
measurement will only start if the test is already started, or when the
test will be started.
STS/AU Path AIS-P/AU-AIS
,
LOP-P/AU-LOP
,
RDI-P/HP-RDI
,
REI-P/HP-REI
,
B3
,
UNEQ-P/HP-UNEQ
,
PDI-P (SONET)
VT/TU Path AIS-V/TU-AIS
,
LOP-V/TU-LOP
,
UNEQ-V/LP-UNEQ
,
RDI-V/LP-RDI
,
REI-V/LP-REI
,
BIP-2
DS1 AIS
,
OOF
,
RAI
,
Framing Bit
,
CRC-6
DS3 AIS
,
OOF
,
Idle
,
RDI
,
F-Bit
,
C-Bit
,
P-Bit
,
FEBE
E1 AIS
,
CRC-4
,
E-Bit
,
LOMF
,
TS16 AIS
,
LOF
,
FAS
,
RAI
,
RAI MF
E4
,
E3
,
E2
AIS
,
LOF
,
FAS
,
RAI
OTL
b
LOF
,
OOF
,
LOL
,
LOR
,
OOR
,
Inv. Marker
,
FAS
FEC
FEC CORR
,
FEC UNCORR
OTUk
c
AIS
,
LOF
,
OOF
,
LOM
,
OOM
,
BDI
,
IAE
,
BIAE
,
BIP-8
,
BEI
,
FAS
,
MFAS
ODUk
AIS
,
OCI
,
LCK
,
BDI
,
BIP-8
,
BEI
,
FSF
,
BSF
,
FSD
,
BSD
AIS
,
CSF, PLM
d
, MSIM
e
, LOOMFI
, OOMFI
BER
g
Pattern Loss
,
Bit Error
(default)
a.
Not available with QSFP transceivers.
b.
The service disruption time measurement is available per lane for OTL defects at the exception of LOL
which is global for all lanes. Refer to
on page 437 for results per lanes.
c.
Only available on the top layer.
d.
Available when the PLM check box is selected (refer to page 180 for more information).
e.
Available with multiplex test only.
f.
Available with OPU4 only.
g.
Available when the
No Pattern Analysis (Live)
check box (see page 139) is cleared.
Layer
Defect
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......