Test Functions
Power Blazer
591
OH - SONET/SDH
OH - SONET/SDH
The SONET/SDH OH page allows modifying (TX) the overhead information
to be transmitted and viewing (RX) the overhead information received.
For
SONET/SDH BERT
, from the
Test
menu, tap
Functions
, and the
OH
tab.
For
OTN-SONET/SDH BERT
, from the
Test
menu, tap
Functions
,
OH
, and
the
SONET/SDH
sub tab.
Tap on any overhead byte in TX to modify its value.
Tap on any overhead byte in RX to see its detailed content/value.
Note:
A byte in TX that has no value displayed or is grayed out, is not configurable
from the OH tab.
TX and RX Buttons (SDH)
Tap on the TX or RX button to respectively access the overhead bytes in
transmission or receive mode.
STS-1 Timeslot/STM-1 Channel
Allows selecting the timeslot number for the Transport OH bytes. The
STS/AU/TU-3 overhead bytes are always for the timeslot selected in the test
configuration. Furthermore when modifying the Transport OH bytes H1 SS
bits, the modification applies to all timeslots when the test topology is
Coupled
. Choices are
1
(default) to
192
(SONET) /
64
(SDH) depending on
the OC-N/STM-N interface selected.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......