Test Functions
Power Blazer
585
OH - OTN
OH - OTN
For
OTN BERT
, from the
Test
menu, tap
Functions
, and the
OH
tab.
For
OTN SONET/SDH BERT
, from the
Test
menu, tap
Functions
,
OH
, and
the
OTN
sub tab.
Allows respectively modifying the overhead information to be transmitted
or viewing the overhead information received.
OTUx/ODUx and ODUx Buttons
Tap on either the
OTUx
/
ODUx
or the
ODUx
button to select the OH level.
Default OTN OH
Returns all TX overhead bytes to their factory default values.
TX/RX
Overhead bytes are organized using rows and columns structure as per
G.709 standard.
Row 1
OA1
and
OA2
, columns 1-6, OTU FAS: All the Frame Alignment Signal
OA1
bytes and
OA2
bytes are individually configurable from
00
to
FF
.
The default values are
F6
for all
OA1
bytes and
28
for all
OA2
bytes.
MFAS
, column 7, OTU MFAS: The Multi-Frame Alignment Signal byte is
not configurable.
SM
, columns 8-10, OTU OH: The Section Monitoring contains the
following bytes.
The first SM byte (column 8) contains the TTI multiframe byte that is
only configurable from
The second SM byte (column 9) contains the BIP-8 byte that is
automatically generated for each frame. This byte is not configurable.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......