Test Results
Power Blazer
409
Alarms/Errors Overview
WIS
Note:
Available under the WIS sub tab for 10G WAN interface only.
Alarms
WIS Link Down
RX
: At least one of the following errors is present: AIS-P, LOF, PLM-P,
SEF, LOP, or AIS-L.
SEF
(Severely Errored Framing)
RX
: A minimum of four consecutive errored framing patterns.
TX
: Generates more than four consecutive errored framing patterns.
LOF
(Loss Of Frame)
RX
: A Severely Error Framing (SEF) defect on the incoming SONET
signal persists for at least 3 milliseconds.
TX
: Generates a non-valid framing pattern.
AIS-L
(Alarm Indication Signal - Line)
RX
: Bits 6, 7 and 8 of the K2 byte contain the “111" pattern in five
consecutive frames.
TX
: Generates a “111” pattern for the bits 6, 7 and 8 of the K2 byte.
RDI-L
(Remote Defect Indication - Line)
RX
: Bits 6, 7, and 8 of the K2 byte contain the “110" pattern in five
consecutive frames.
TX
: Generates a “110” pattern for the bits 6, 7 and 8 of the K2 byte.
AIS-P
(Alarm Indication Signal - Path)
RX
: The H1 and H2 bytes for a STS path contain an all-ones pattern in
three consecutive frames or more.
TX
: Generates an all-ones pattern for H1 and H2 bytes.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......