Test Setup - Test Configurator, Timer, and System
Power Blazer
133
1588 PTP
GM IP Address
1
is the IP address of the Grand Master Clock used by
the 1588 PTP function to communicate with it.
Quick Ping
button allows testing if the Grand Master IP address can
be reached. A message is returned indicating if the ping attempt was
Successful
or
Failed
.
IP
TOS/DS
allows entering the Type of Service:
0x00
(default) to
0xFF
.
Mechanism
is not selectable and is set to
Delay Req-Resp
(Delay
Request-Response) which specifies the mechanism used by the
1588 PTP function to communicate with the Grand Master clock. Refer
to
Delay Request-Response
on page 697 for more information.
Delay Mode
is not selectable and is set to
Two-way
which uses
Sync/Follow Up, Delay Request, and Delay Response messages.
Connect
button is used to initiate the Grand Master Connection
process. This process is also automatically initiated when starting the
test if not already initiated. The process automatically ends when
stopping the test.
Negotiation Status
is displayed during the Unicast negotiation
process which is initiated when either the test is started or the
Connect
information.
1. Only available with Unicast mode.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......