Test Control
Power Blazer
643
Lpbk Tool Button (Loopback Tool)
S-OAM Responder
check box when selected (default) allows
responding to LBM, LTM, DMM, LMM, and SLM valid messages
(
Lpbk Tool
must be started, see
Loopback
button below). Traffic
statistics are also monitored (refer to
Responder - TX Count
reports respectively the count of LBR, LTR,
DMR, LMR, SLR, and the total of frames transmitted.
Responder - RX Count
reports counts of valid LBM, LTM, DMM,
LMM, SLM, and the total of frames received. A valid messages must
have its destination MAC address matching either the unit port
Unicast MAC address or a Multicast class 1 address
1
.
Loopback
button starts/stops looping back the frames/packets that are
received. The default value is disabled.
Responds to... message
Responds with... message
LBM
LBR
LTM
LTR
DMM
DMR
LMM
LMR
SLM
SLR
1. Refer to
Unicast/Multicast Addresses for Ethernet OAM
on page 757 for more information.