Test Setup - Test Configurator, Timer, and System
Power Blazer
321
Streams - Profile
Total TX Rate
indicates the percentage of the total line utilization
which is the sum of all TX rate enabled streams.
Note:
The Individual stream can be enabled/disabled even when the test is
started and running. The streams can be enabled one after the other, up to
16, as long as the maximum rate is not reached. For example, if the first
stream is using the full rate available, then no other stream can be enabled.
However, if the first enabled stream uses half rate, then at least another
stream can be enabled using up to half rate. Thus, to enable a second
stream, first set the TX rate value within the non-used rate, then enable it. A
stream cannot be enabled if its MAC address is not valid (it can be either
not resolved or wrongly entered).
Link Capacity
indicates the total rate available for traffic generation.
QoS Metrics
Note:
QoS Metrics settings apply to all streams.
Global Pass/Fail Verdict
check box when selected (default) enables
the pass/fail verdict for all streams.
Global Thresholds Type
button
Throughput
allows selecting if the verdict is based on the
Current
Throughput
(default) or
Average Throughput
.
Frame Loss
allows selecting if the verdict is based on a frame loss
Count
(default) or
Rate
.
Out-of-Sequence
allows selecting if the verdict is based on an
Out-of-Sequence
Count
(default) or
Rate
.
Throughput (%)
check box when selected enables the throughput
pass/fail verdict and allows setting the minimum and maximum
threshold values.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......