7A-14 Heater and Ventilation:
Blower Motor Removal and Installation
S3RH0A7106003
Removal
1) Disconnect negative (–) cable at battery.
2) Remove glove box.
3) Disconnect blower motor connector (1).
4) Remove blower motor (2).
Installation
Reverse removal procedure to install blower motor.
Blower Motor Inspection
S3RH0A7106004
• Check motor coil for continuity between terminals as
shown. If there are no continuity, replace blower motor
assembly (1).
• Check motor for smooth operation and current.
1) Fix blower motor assembly (1) using soft-jawed vise.
2) Connect battery to blower motor assembly (1) as
shown.
3) Check if blower motor operates smoothly and
doesn’t make abnormal noise.
4) Check if ammeter indicates specified current.
If current is out of specification, replace blower
motor.
Reference
Blower specified current at 12 V 20 A maximum
Blower Motor Controller Removal and
Installation
S3RH0A7106005
Removal
1) Disconnect negative (–) cable at battery.
2) Disconnect blower motor controller connector.
3) Remove blower motor control (1).
Installation
Reverse removal procedure to install blower motor
controller.
2
1
I2RH01710007-01
I2RH01710008-01
I2RH01710009-01
1
I4RH01722039-01
Summary of Contents for Liana RH413
Page 2: ......
Page 4: ......
Page 6: ......
Page 336: ...1K 4 Exhaust System...
Page 456: ...3D 4 Propeller Shafts...
Page 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Page 1044: ...8B 119 Air Bag System...
Page 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Page 1278: ...9M 3 Exterior Trim...
Page 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Page 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Page 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...