Air Conditioning System: Automatic Type 7B-64
Temperature control actuator position sensor circuit inspection
6
1) Turn ignition switch OFF, and then disconnect HVAC
control module connector referring to “HVAC Control
Module Removal and Installation in Section 7A”.
2) Check resistance between “GRY” wire terminal and
body ground.
Is resistance more than 1 M
Ω
?
Poor connection of
“GRY” wire terminal at
HVAC control module
connector, and/or HVAC
control module faulty.
“GRY” wire shorted to
ground.
Step
Action
Yes
No
Step
Action
Yes
No
1
1) Turn ignition switch OFF, and then disconnect
temperature control actuator referring to “Temperature
Control Actuator Removal and Installation in Section
7A”.
2) Turn ignition switch ON, and then check voltage
between “RED/WHT” wire terminal at temperature
control actuator connector and body ground.
Is voltage about 5 V?
Go to Step 3.
Go to Step 2.
2
1) Turn ignition switch OFF, and then disconnect HVAC
control module connector referring to “HVAC Control
Module Removal and Installation in Section 7A”.
2) Check resistance between “RED/WHT” wire terminal at
temperature control actuator connector and “RED/WHT”
wire terminal at HVAC control module connector.
Is resistance less than 1 M
Ω
?
Go to Step 3.
“RED/WHT” wire open
or high resistance, poor
connection of “RED/
WHT” wire terminal at
HVAC control module
connector, and/or HVAC
control module faulty.
3
1) With ignition switch ON position and HVAC control
module connector connected, check voltage between
“RED/WHT” wire terminal and “BLK/RED” wire terminal
at temperature control actuator connector.
Is voltage about 5 V?
Go to Step 4.
“BLK/RED” wire open or
high resistance, poor
connection of “BLK/
RED” wire terminal at
HVAC control module
connector, and/or HVAC
control module faulty.
4
1) With ignition switch ON position, check voltage between
“WHT” wire terminal and “BLK/RED” wire terminal at
temperature control actuator connector.
Is voltage about 2.5 V?
Go to Step 6.
Go to Step 5.
5
1) Turn ignition switch OFF, disconnect HVAC control
module connector.
2) Check resistance between “WHT” wire terminal at
temperature control actuator connector and “WHT” wire
terminal at HVAC control module connector.
Is resistance less than 1 M
Ω
?
Go to Step 6.
“WHT” wire open or
high resistance, poor
connection of “WHT”
wire terminal at HVAC
control module
connector, and/or HVAC
control module faulty.
6
1) Check temperature control actuator referring to
“Temperature Control Actuator Inspection in Section 7A”.
Is temperature control actuator normal?
HVAC control module
faulty.
Temperature control
actuator faulty.
Summary of Contents for Liana RH413
Page 2: ......
Page 4: ......
Page 6: ......
Page 336: ...1K 4 Exhaust System...
Page 456: ...3D 4 Propeller Shafts...
Page 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Page 1044: ...8B 119 Air Bag System...
Page 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Page 1278: ...9M 3 Exterior Trim...
Page 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Page 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Page 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...