7B-23 Air Conditioning System: Manual Type
Operation Procedure for Refrigerant Charging
S3RH0A7216002
WARNING
!
• Your eyes should not be exposed to refrigerant (liquid).
Any liquid HFC-134a (R-134a) escaping by accident shows a temperature as low as approximately –
6
°
C (21.2
°
F) below freezing point. Should liquid HFC-134a (R-134a) get into your eyes, it may cause
a serious injury. To protect your eyes against such accident, it is necessary to always wear goggles.
Should it occur that HFC-134a (R-134a) strikes your eyes, consult a doctor immediately.
– Do not use your hand to rub the affected eye(s). Instead, use quantities of fresh cold water to
splash it over the affected area to gradually raise temperature of such area above freezing point.
– Obtain proper treatment as soon as possible from a doctor or eye specialist.
• Should the HFC-134a (R-134a) liquid come into contact with your skin, the affected area should be
treated in the same manner as when skin is frostbitten or frozen.
• Refrigerant must not be handled near where welding or steam cleaning is performed.
• Refrigerant should be kept at a cold and dark place. It should never be stored where a high
temperature is anticipated, e.g. where exposed to direct sun light, close to fire or inside vehicle
(including trunk room).
• Avoid breathing fumes produced when HFC-134a (R-134a) is burned. Such fumes may be hazardous
to health.
Recovery
When evacuating A/C system, always recover
refrigerant by using equipment for refrigerant recovery
and recycling equipment. Discharging refrigerant HFC-
134a (R-134a) into atmosphere would cause adverse
effect to environments.
NOTE
• After recovering refrigerant from system,
the amount of removed compressor oil
must be measured for replenishing
compressor oil.
• When handling recovery and recycling
equipment, be sure to follow the
instruction manual for the equipment.
Step
Action
Yes
No
1
1) Replenish compressor oil referring to “Replenishing
2) Start evacuating, and then wait 15 minutes referring to
“Evacuating of A/C System: Manual Type”.
3) Stop evacuating, and then wait 10 minutes.
4) Check system for pressure leakage referring to
“Checking of A/C System for Pressure Leaks: Manual
Type”.
Does gauge show normal condition?
Go to Step 2.
Inspect and repair
connections, and then
go to Step 1.
2
1) Charge A/C system with refrigerant referring to
“Procedure of Charging: Manual Type”.
Amount of refrigerant
500
±
30 g (17.65
±
1.05 oz)
2) Check system for refrigerant leaks referring to “Checking
of A/C System for Refrigerant Leaks: Manual Type”, and
then perform “A/C System Performance Inspection”.
Does A/C system operate properly?
End.
Inspect and repair
connections, and then
go to Step 1.
Summary of Contents for Liana RH413
Page 2: ......
Page 4: ......
Page 6: ......
Page 336: ...1K 4 Exhaust System...
Page 456: ...3D 4 Propeller Shafts...
Page 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Page 1044: ...8B 119 Air Bag System...
Page 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Page 1278: ...9M 3 Exterior Trim...
Page 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Page 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Page 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...