7A-4 Heater and Ventilation:
Diagnostic Information and Procedures
Heater and Ventilation Symptom Diagnosis
S3RH0A7104001
Condition
Possible cause
Correction / Reference Item
Blower motor does not
operate with blower
speed selector ON.
Fuse blown
Check “Blower motor” fuse and check for short
circuit for ground.
Blower motor relay faulty
Check relay referring to “Blower Motor Relay
Inspection”.
Blower motor controller faulty
Check blower motor controller referring to
“Blower Motor Controller Inspection”.
Blower speed selector faulty
Check HVAC control module and its circuit
referring to “Inspection of HVAC Control
Module and its Circuit”.
Blower motor faulty
Check blower motor referring to “Blower Motor
Inspection”.
Wiring or grounding faulty
Repair as necessary.
Incorrect temperature
output
Temperature selector door faulty
Replace air flow selector door referring to
“Heater Unit Removal and Installation”.
Heater hoses leaking or clogged
Replace hoses.
Heater core leaking or clogged
Replace heater core referring to “Heater Unit
Removal and Installation”.
Temperature control actuator faulty
Check temperature control actuator referring to
“Temperature Control Actuator Inspection”.
Temperature selector faulty
Check HVAC control module and its circuit
referring to “Inspection of HVAC Control
Module and its Circuit”.
Wiring or grounding faulty
Repair as necessary.
When air flow selector is
changed, damper position
doesn’t match air outlet
Air flow selector door faulty
Replace air flow selector door referring to
“Heater Unit Removal and Installation”.
Air flow control actuator faulty
Check air flow control actuator referring to “Air
Flow Control Actuator Inspection”.
Air flow selector faulty
Check HVAC control module and its circuit
referring to “Inspection of HVAC Control
Module and its Circuit”.
Wiring or grounding faulty
Repair as necessary.
Air intake door doesn’t
change when air intake
mode is changed.
Air intake selector door faulty
Replace air intake selector door referring to
“Blower Unit Removal and Installation”.
Air intake control actuator faulty
Check air intake control actuator referring to
“Air Intake Control Actuator Inspection”.
Air intake switch faulty
Check HVAC control module referring to
“Inspection of HVAC Control Module and its
Circuit”.
Wiring or grounding faulty
Repair as necessary.
Summary of Contents for Liana RH413
Page 2: ......
Page 4: ......
Page 6: ......
Page 336: ...1K 4 Exhaust System...
Page 456: ...3D 4 Propeller Shafts...
Page 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Page 1044: ...8B 119 Air Bag System...
Page 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Page 1278: ...9M 3 Exterior Trim...
Page 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Page 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Page 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...