7B-21 Air Conditioning System: Manual Type
G41-14
LT GRN
ECT sensor
input
Ground to
engine (Fig B)
0.71 – 0.77 V
(298 – 320
Ω
)
Engine coolant temperature at
approximately 80
°
C (176
°
F) with
engine running
0.35 – 0.37 V
(135 – 144
Ω
)
Engine coolant temperature at
approximately 110
°
C (230
°
F) with
engine running
*If the temperature is more than 110
°
C
(230
°
F), compressor and condenser
cooling fan should be stop (come back
at less than 108
°
C (226.4
°
F)
G04-1
BRN/YEL
Compressor
magnet clutch
relay output
Ground to
engine (Fig B)
0 – 1 V
Fulfill all the following conditions
• Blower speed selector ON
• A/C or defroster switch ON
• Engine running
12 – 15 V
Except the above-mentioned condition
with engine running
G04-5
BLK/RED
Main power
supply for ECM
Ground to
engine (Fig B)
10 – 14 V
Ignition switch ON with engine stopped
G04-6
BLK/RED
Main power
supply for ECM
Ground to
engine (Fig B)
10 – 14 V
Ignition switch ON with engine stopped
G04-7
BLU/ORN
Radiator cooling
fan and A/C
condenser fan
control pressure
switch input
Ground to
engine (Fig B)
–0.5 – 0.5 V
Radiator cooling fan control pressure of
A/C refrigerant pressure switch ON
12 – 15 V
Radiator cooling fan control pressure of
A/C refrigerant pressure switch OFF
G04-9
BLU/YEL
Condenser
cooling fan relay
output
Ground to
engine (Fig B)
0 – 1 V
Fulfill all the following conditions
• Blower speed selector ON
• A/C or defroster switch ON
• Engine running
Engine coolant temperature at more
than 110
°
C (230
°
F) with engine
running
12 – 15 V
Except the above-mentioned condition
with engine running
G04-10
BRN/WHT Main relay drive
Ground to
engine (Fig B)
0.5 – 1.2 V
Ignition switch ON with engine stopped
10 – 14 V
Ignition switch OFF
G04-11
YEL/WHT
A/C evaporator
inlet air
temperature
sensor input
Ground to
engine (Fig B)
2.07 – 2.18 V
(1914 – 2090
Ω
)
A/C evaporator inlet air temperature at
approximately 25
°
C (77
°
F) with engine
running
2.46 – 2.57 V
(2697 – 2870
Ω
)
A/C evaporator inlet air temperature at
approximately 18
°
C (64.4
°
F) with
engine running
G04-14
WHT/BLK
A/C evaporator
outlet air
temperature
sensor input
Ground to
engine (Fig B)
2.07– 2.18 V
(1914 – 2090
Ω
)
A/C evaporator outlet air temperature at
approximately 25
°
C (77
°
F) with engine
running
3.32 – 3.39 V
(5381 – 5713
Ω
)
A/C evaporator outlet air temperature at
approximately 3.5
°
C (38.3
°
F) with
engine running
G04-16
GRN/BLK A/C switch input
Ground to
engine (Fig B)
12 – 15 V
Fulfill all the following conditions
• Blower speed selector ON
• A/C or defroster switch ON
• Engine running
0 – 1 V
Except the above-mentioned condition
with engine running
Terminal Wire Color
Circuit
Measurement
Ground
Normal Value
Condition
Summary of Contents for Liana RH413
Page 2: ......
Page 4: ......
Page 6: ......
Page 336: ...1K 4 Exhaust System...
Page 456: ...3D 4 Propeller Shafts...
Page 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Page 1044: ...8B 119 Air Bag System...
Page 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Page 1278: ...9M 3 Exterior Trim...
Page 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Page 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Page 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...