7B-15 Air Conditioning System: Manual Type
G77-6
BLU/WHT
Blower motor control
voltage feedback
10.0 – 14.0 V Ignition switch ON, Blower speed selector OFF
about 8.0 V
Ignition switch ON, Blower speed selector 1st
position
about 6.5 V
Ignition switch ON, Blower speed selector 2nd
position
about 5.5 V
Ignition switch ON, Blower speed selector 3rd
position
about 4.8 V
Ignition switch ON, Blower speed selector 4th
position
about 3.8 V
Ignition switch ON, Blower speed selector 5th
position
about 3.0 V
Ignition switch ON, Blower speed selector 6th
position
about 2.0 V
Ignition switch ON, Blower speed selector 7th
position
about 1.0 V
Ignition switch ON, Blower speed selector high
position
G77-7
BLU
Serial communication
line of data link
connector
10.0 – 14.0 V Ignition switch ON
G77-8
—
—
—
—
G77-9
BRN/RED Sensor ground
about 0.0 V Full-time
G77-10
—
—
—
—
G77-11
—
—
—
—
G77-12 WHT/BLU
Air flow control actuator
position sensor
about 1.0 V Ignition switch ON, Air flow selector DEF position
about 4.0 V Ignition switch ON, Air flow selector VENT position
G77-13
BLK
Illumination ground
0.0 V
Full-time
G77-14
RED/YEL Illumination switch
0.0 V
Ignition switch ON, Lighting switch OFF position
10.0 – 14.0 V Ignition switch ON, Lighting switch ON position
G77-15 WHT/RED
Electric power source for
backup
10.0 – 14.0 V Full-time
G77-16
RED/BLK Electric power source
10.0 – 14.0 V Ignition switch ON
G77-17 GRY/RED
Air flow control actuator
(DEF)
10.0 – 14.0 V
Ignition switch ON, Air flow control actuator is
working in operation from VENT to DEF position
about 0.0 V Ignition switch ON, except the above condition
G77-18
GRY/BLK
Air flow control actuator
(FACE)
10.0 – 14.0 V
Ignition switch ON, Air flow control actuator is
working in operation from DEF to VENT position
about 0.0 V Ignition switch ON, except the above condition
G77-19
GRY/BLU
Temperature control
actuator (COOL)
10.0 – 14.0 V
Ignition switch ON, Temperature control actuator is
working in operation from HOT to COOL position
about 0.0 V Ignition switch ON, except the above condition
G77-20
GRY
Temperature control
actuator (HOT)
10.0 – 14.0 V
Ignition switch ON, Temperature control actuator is
working in operation from COOL to HOT position
about 0.0 V Ignition switch ON, except the above condition
G77-21 YEL/GRN
Air intake actuator
(FRESH AIR)
about 0.0 V Ignition switch ON, Air intake switch OFF position
10.0 – 14.0 V Ignition switch ON, Air intake switch ON position
G77-22
YEL/RED
Air intake actuator
(RECIRCULATION AIR)
about 0.0 V Ignition switch ON, Air intake switch ON position
10.0 – 14.0 V Ignition switch ON, Air intake switch OFF position
G77-23
—
—
—
—
G77-24
—
—
—
—
G77-25 BLK/ORN Ground
about 0.0 V Full-time
G77-26 RED/WHT
Air flow control actuator
and Temperature control
actuator
about 5.0 V Ignition switch ON
G77-27
—
—
—
—
Terminal Wire Color
Circuit
Normal
Voltage
Condition
Summary of Contents for Liana RH413
Page 2: ......
Page 4: ......
Page 6: ......
Page 336: ...1K 4 Exhaust System...
Page 456: ...3D 4 Propeller Shafts...
Page 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Page 1044: ...8B 119 Air Bag System...
Page 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Page 1278: ...9M 3 Exterior Trim...
Page 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Page 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Page 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...