7B-65 Air Conditioning System: Automatic Type
DTC B1514 (No.14): Air Flow Control Actuator and/or its Circuit malfunction
S3RH0A7224019
Wiring Diagram
DTC Detecting Condition and Trouble Area
DTC Troubleshooting
NOTE
First, perform “Air flow control actuator motor circuit inspection: Automatic Type”. After that, if DTC
1514 is still detected, perform “Air flow control actuator position sensor circuit inspection: Automatic
Type”.
Air flow control actuator motor circuit inspection
M
12V
5V
5V
RED/WHT
WHT/BLU
BLK/RED
GRY/RED
GRY/BLK
G77-9
G77-12
G77-26
G77-18
G77-17
2
1
3
9
12
26
17
18
I3RH0A722016-01
1. HVAC control module
2. Air flow control actuator
3. HVAC control module connector “G77” (viewed from harness side)
DTC Detecting Condition
Trouble Area
• Signal from air flow control position sensor is less than the specified (3.4
V) in operation to FACE direction after 15 seconds.
• Signal from air flow control position sensor is more than the specified (1.6
V) in operation to DEF direction after 15 seconds.
• “GRY/RED”, “GRY/BLK”, “RED/
WHT”, “WHT/BLU” and/or “BLK/
RED” wire faulty
• Linkage faulty
• Heater and cooling unit faulty
• Air flow control actuator faulty
• HVAC control module faulty
Step
Action
Yes
No
1
1) Check if there is any obstruction in operating range of
actuator linkage and if actuator linkage operates
smoothly.
Is there any obstruction? Does actuator linkage operate
smoothly?
Obstruction in operating
range of actuator
linkage, actuator linkage
faulty, and/or internal
fault of heater and
cooling unit.
Go to Step 2.
2
1) Turn ignition switch OFF, and then disconnect air flow
control actuator connector referring to “Air Flow Control
Actuator Removal and Installation in Section 7A”.
2) Turn ignition switch ON, and then check voltage
between “GRY/RED” wire terminal at air flow control
actuator connector and body ground.
Is voltage about 12 V?
Go to Step 5.
Go to Step 3.
3
1) Turn ignition switch OFF, and then disconnect HVAC
control module connector referring to “HVAC Control
Module Removal and Installation in Section 7A”.
2) Check resistance between “GRY/RED” wire terminal at
air flow control actuator connector and “GRY/RED” wire
terminal at HVAC control module connector.
Is resistance less than 1 M
Ω
?
Go to Step 4.
“GRY/RED” wire open
or high resistance.
Summary of Contents for Liana RH413
Page 2: ......
Page 4: ......
Page 6: ......
Page 336: ...1K 4 Exhaust System...
Page 456: ...3D 4 Propeller Shafts...
Page 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Page 1044: ...8B 119 Air Bag System...
Page 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Page 1278: ...9M 3 Exterior Trim...
Page 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Page 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Page 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...