ADC Control Registers
737
SPNU503C – March 2018
Copyright © 2018, Texas Instruments Incorporated
Analog To Digital Converter (ADC) Module
19.11.10 ADC Group2 Trigger Source Select Register (ADG2SRC)
ADC Group2 Trigger Source Select Register (ADG2SRC) is shown in
and described in
.
Figure 19-30. ADC Group2 Trigger Source Select Register (ADG2SRC) [offset = 24h]
31
8
Reserved
R-0
7
5
4
3
2
0
Reserved
G2_EDG_BOTH
G2_EDG_SEL
G2_SRC
R-0
R/W-0
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 19-15. ADC Group2 Trigger Source Select Register (ADG2SRC) Field Descriptions
Bit
Field
Value
Description
31-5
Reserved
0
Reads return zeros, writes have no effect.
4
G2_EDG_BOTH
Group2 Trigger Edge Polarity Select. This bit configures the group2 to be triggered on both rising
and falling edge detected on the selected trigger source.
Any operation mode read/write:
0
The conversion is triggered only upon detecting an edge defined by the G2_EDG_SEL bit.
1
The conversion is triggered upon detecting either a rising or falling edge.
3
G2_EDG_SEL
Group2 Trigger Edge Polarity Select. This bit determines the polarity of the transition on the
selected source that triggers the Group2 conversion.
Any operation mode read/write:
0
A high-to-low transition on the selected source will trigger the Group2 conversion.
1
A low-to-high transition on the selected source will trigger the Group2 conversion.
2-0
G2_SRC
Group2 Trigger Source.
Any operation mode read/write:
0-7h
The ADC module allows a trigger source to be selected for the Group2 from up to eight options.
These options are device-specific and the device specification must be referred to identify the
actual trigger sources.