System and Peripheral Control Registers
147
SPNU503C – March 2018
Copyright © 2018, Texas Instruments Incorporated
Architecture
Table 2-44. PLL Control Register 1 (PLLCTL1) Field Descriptions
Bit
Field
Value
Description
31
ROS
Reset on PLL Slip
0
Do not reset system when PLL slip is detected.
1
Reset when PLL slip is detected.
Note: MASK_SLIP (Bits 30-29) must also be enabled for ROS to be enabled.
30-29
MASK_SLIP
Mask detection of PLL slip
2h
Bypass on PLL Slip is disabled. If a PLL Slip is detected no action is taken.
Others
Bypass on PLL Slip is enabled. If a PLL Slip is detected the device will automatically bypass the
PLL and use the oscillator to provide the device clock.
Note: If ROS (Bit 31) is set to 1, the device will be reset if a PLL Slip and the PLL will be
bypassed after the reset occurs.
28-24
PLLDIV
PLL Output Clock Divider
R = 1
f
PLL CLK
= f
post_ODCLK
/ R
0
f
PLL CLK
= f
post-ODCLK
/ 1
1h
f
PLL CLK
= f
post-ODCLK
/ 2
:
:
1Fh
f
PLL CLK
= f
post-ODCLK
/ 32
23
ROF
Reset on Oscillator Fail
0
Do not reset system when oscillator is out of range.
1
Reset system when oscillator is out of range.
22
Reserved
0
Value has no effect on PLL operation.
21-16
REFCLKDIV
Reference Clock Divider
NR = REF 1
f
INT CLK
= f
OSCIN
/ NR
0
f
INT CLK
= f
OSCIN
/ 1
1h
f
INT CLK
= f
OSCIN
/ 2
:
:
3Fh
f
INT CLK
= f
OSCIN
/ 64
15-0
PLLMUL
PLL Multiplication Factor
NF = (PLLMUL / 256) + 1, valid multiplication factors are from 1 to 256.
f
VCO CLK
= f
INT CLK
x NF
0h
f
VCO CLK
= f
INT CLK
x 1
100h
f
VCO CLK
= f
INT CLK
x 2
:
:
5B00h
f
VCO CLK
= f
INT CLK
x 92
5C00h
f
VCO CLK
= f
INT CLK
x 93
:
:
FF00h
f
VCO CLK
= f
INT CLK
x 256