Instruction Set
940
SPNU503C – March 2018
Copyright © 2018, Texas Instruments Incorporated
High-End Timer (N2HET) Module
20.6.3.15 MOV64 (Data Move 64)
Syntax
MOV64 {
[brk={OFF | ON}]
[next={label | 9-bit unsigned integer}]
remote={label | 9-bit unsigned integer}
[request={NOREQ | GENREQ | QUIET}]
[control={OFF | ON}]
[en_pin_action={OFF | ON}]
[cond_addr={label | 9-bit unsigned integer}]
[pin={pin number}]
comp_mode={ECMP | SCMP | MCMP1 | MCMP2}
[action={CLEAR | SET | PULSELO | PULSEHI}]
[reg={A | B | R | S | T | NONE}]
[irq={OFF | ON}]
[data={25-bit unsigned integer]
[hr_data= {7-bit unsigned integer}
}
-or-
Syntax
MOV64 {
[brk={OFF | ON}]
[next={label | 9-bit unsigned integer}]
remote={label | 9-bit unsigned integer}
cntl_val={29-bit unsigned integer}
[data={25-bit unsigned integer]
[hr_data= {7-bit unsigned integer}
}