Instruction Set
898
SPNU503C – March 2018
Copyright © 2018, Texas Instruments Incorporated
High-End Timer (N2HET) Module
hr_lr*
Specifies HIGH/LOW data resolution. If the hr_lr field is HIGH, the instruction uses the
hr_data field. If the hr_lr field is LOW, the hr_data field is ignored.
Default: HIGH
Location: Program Field [8]
hr_lr
Prog. field [8]
LOW
1
HIGH
0
prv*
Specifies the initial value defining the previous bit (see
). A value of
ON sets the previous pin-level bit to 1. A value of OFF sets the initial value of the
previous (prv) bit to 0. The prv bit is overwritten (set or reset) by the N2HET the first
time the instruction is executed.
Default: OFF
Location: Control Field [25]
cntl_val*
Available for DADM64, MOV64, and RADM64, this bit field allows the user to specify
the replacement value for the remote control field.
comp_mode*
Specifies the compare mode. This field is used with the 64-bit move instructions. This
field ensures that the sub-opcodes are moved correctly.
Default: ECMP
Location: Control Field [6:5]
Action
C[6]
C[5]
Order
ECMP
0
0
SCMP
0
1
MCMP1
1
0
REG_GE_DATA
MCMP2
1
1
DATA_GE_REG