10
11
12
1
1
0
1
Angle
count
HET
res.
Angle
increment
Resolution
Angle increment
HET
HWAG
HET Interface
HWAG core
Toothed wheel
B
U
S
I
/
F
To CPU
Angle Functions
844
SPNU503C – March 2018
Copyright © 2018, Texas Instruments Incorporated
High-End Timer (N2HET) Module
20.3.2.4 Hardware Angle Generator and High-End Timer
In the engine management application, the HWAG is usually connected to one or more high-end timers.
This connection allows you to perform angle compare and angle/time compare. For an example of the
hardware angle generator/high-end timer interface, see
.
Figure 20-50. Hardware Angle Generator/High End Timer Interface
20.3.2.4.1 Signal Description
To perform a resynchronization, the HWAG interface provides to the NHET at every resolution clock an
angle increment value that represents how much the angle counter of the HWAG has been incremented
since the last NHET resolution clock. For an example of the angle count within the HWAG, see
Figure 20-51. Angle Count Within the HWAG at Resolution Clock