Control Registers and Control Packets
604
SPNU503C – March 2018
Copyright © 2018, Texas Instruments Incorporated
Direct Memory Access Controller (DMA) Module
16.3.1.55 DMA Memory Protection Status Register (DMAMPST)
Figure 16-71. DMA Memory Protection Status Register (DMAMPST) [offset = 1B4h]
31
25
24
23
17
16
Reserved
REG3FT
Reserved
REG2FT
R-0
R/W1C-0
R-0
R/W1C-0
15
9
8
7
1
0
Reserved
REG1FT
Reserved
REG0FT
R-0
R/W1C-0
R-0
R/W1C-0
LEGEND: R/W = Read/Write; R = Read only; W1C = Write 1 to clear; -
n
= value after reset
Table 16-63. DMA Memory Protection Status Register (DMAMPST) Field Descriptions
Bit
Field
Value
Description
31-25
Reserved
0
Reads return 0. Writes have no effect.
24
REG3FT
Region 3 fault. This bit determines whether an access permission violation was detected in this region.
0
Read: No fault was detected.
Write: No effect.
1
Read: A fault was detected.
Write: The bit was cleared.
23-17
Reserved
0
Reads return 0. Writes have no effect.
16
REG2FT
Region 2 fault. This bit determines whether an access permission violation was detected in this region.
0
Read: No fault was detected.
Write: No effect.
1
Read: A fault was detected.
Write: The bit was cleared.
15-9
Reserved
0
Reads return 0. Writes have no effect.
8
REG1FT
Region 1 fault. This bit determines whether an access permission violation was detected in this region.
0
Read: No fault was detected.
Write: No effect.
1
Read: A fault was detected.
Write: The bit was cleared.
7-1
Reserved
0
Reads return 0. Writes have no effect.
0
REG0FT
Region 0 fault. This bit determines whether an access permission violation was detected in this region.
0
Read: No fault was detected.
Write: No effect.
1
Read: A fault was detected.
Write: The bit was cleared.