PMM Registers
210
SPNU503C – March 2018
Copyright © 2018, Texas Instruments Incorporated
Power Management Module (PMM)
3.4.3 Power Domain Clock Disable Register (PDCLKDISREG)
The default values of the control fields are determined by the device reset configuration word stored in the
TI-OTP region of flash bank 0.
Figure 3-5. Power Domain Clock Disable Register (PDCLKDISREG) [offset = 20h]
31
8
Reserved
R-0
7
4
3
2
1
0
Reserved
PDCLK_DIS[3]
PDCLK_DIS[2]
PDCLK_DIS[1]
PDCLK_DIS[0]
R-0
R/WP-n
R/WP-n
R/WP-n
R/WP-n
LEGEND: R/W = Read/Write; R = Read only; WP = Write in privileged mode only; -
n
= value after reset
Table 3-4. Power Domain Clock Disable Register (PDCLKDISREG) Field Descriptions
Bit
Field
Value
Description
31-4
Reserved
0
Read returns 0. Writes have no effect.
3
PDCLK_DIS[3]
Read in User and Privileged Mode returns the current value of PDCLK_DIS[3]. Write in Privileged
Mode only.
0
Enable clocks to logic power domain PD5.
1
Disable clocks to logic power domain PD5.
2
PDCLK_DIS[2]
Read in User and Privileged Mode returns the current value of PDCLK_DIS[2]. Write in Privileged
Mode only
0
Enable clocks to logic power domain PD4.
1
Disable clocks to logic power domain PD4.
1
PDCLK_DIS[1]
Read in User and Privileged Mode returns the current value of PDCLK_DIS[1]. Write in Privileged
Mode only.
0
Enable clocks to logic power domain PD3.
1
Disable clocks to logic power domain PD3.
0
PDCLK_DIS[0]
Read in User and Privileged Mode returns the current value of PDCLK_DIS[0]. Write in Privileged
Mode only.
0
Enable clocks to logic power domain PD2.
1
Disable clocks to logic power domain PD2.