Installing a controller
• TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at a circuit breaker or fuse and
test that power is off before wiring in a Levven Controls product.
• Install and/or use Levven Controls in accordance with local electrical codes and
regulations.
• Levven Controls controllers are to be mounted in electrical junction boxes of suitable
size to satisfy the electrical code in your area.
• If you are unsure about any part of these instructions, consult a qualified electrician.
1) Connect wires to the controller (Fig 1)
a. Connect the black power wire to the black wire of the controller
b. Connect the black load wire to the red wire from the controller
c. Connect the white wires from the power, load, and controller together
2) Mount the controller in an electrical box
a. If installing the controller in a steel box, position the controller’s antenna wire outside
the box for best reception. The antenna can be inside a plastic electrical box without
affecting reception.
3) Turn power on
a. When your connections are safely completed, energize the circuit by turning the power
on at the panel.
b. When powered, the LED status indicator on the controller will illuminate.
4) Group controllers together
a. When two or more controllers are installed in a building, grouping controllers together
is required to operate multiple controllers from one switch or using Levven Q for mobile
device access and control. Only controllers with no previously saved group or pairing
can join a group.
b. Press and release the ‘Pair’ button on one of the controllers in the group (or an
ungrouped controller to start a new group). The LED on this controller (C1) will blink
green.
c. Press ‘Pair’ button on new controller being added to the group (C2). Its LED will blink
green, and the first controller’s LED will blink red/green.
d. Press ‘Pair’ button on the first controller (C1) again to complete the grouping. Its LED
will flash green three times to confirm the group setting was saved.
5) How to reset a controller
a. To clear switch pairings from a controller, press and hold the ‘Pair’ button for 5 seconds.
The LED will flash red three times to confirm.
b. To remove a controller from a group, press and hold its ‘Pair’ button for 10 seconds. The
LED will flash red 10 times when the grouping is cleared.
c. If using multiple controllers, group the controller before pairing it to a switch.
6) Pair switches and controllers
a. Press and release the ‘Pair’ button on the controller. The LED on the controller will blink
green. NOTE: If there is no pairing request received within 60 seconds, the controller will
quit the pairing procedure and its LED will return to a solid green.
b. Squeeze then quickly release both ends of the switch to send a pairing code to the
controller. The LED on the controller will blink green and red.
c. Press and release the controller’s ‘Pair’ button to confirm the pairing. Its LED will flash
green to confirm the pairing was saved successfully.
7) Mounting and using switches
a. Levven Controls switches can be secured to any surface. Screws and anchors are
provided to mount switches. Use decorator-style or Designer Series wall plates to finish
the installation.
b. Press and release the top of the switch rocker to send an “on” command to the
controller. Press and release the bottom of the switch rocker to send an “off” command.
Figure 1
Connecting the controller to the line/hot, load, and neutral wires.
Connectez le contrôleur avec les fils de la ligne actif, le charge, et le
neutre. Conecte el control de carga con los cables de la línea fase, la carga y el neutro.
Further Assistance
Detailed support documents, videos, and 1-year limited manufacturer warranty information is available at levven.com/support. Levven Controls
and GoConex by Levven are proudly designed and manufactured in Canada. Telephone Levven Electronics Ltd (780) 391-3000 or email info@
levven.com.
Levven Controls GPC20 controller / contrôleur
Input
/ Alimentation
: 120/250/277VAC, 50/60Hz 0.1~20A. Load
/ Chargement
: 20A max (resistive lighting
/ résistance
de l’éclairage
). Indoor use only
/ Utilisation intérieur seulement
. Operating temperature range
/ S’opère à une température
ente
-40°C – 50°C. FCC ID : 2ADH9-G2CF. This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. IC ID: 12453A-G2CF. CAN ICES-3(B)/NMB-3(B).
Certified to
/ Certifié à
CSA STD C22.2 #14 Conforms to
/ Conforme à
UL STD 244A &508
Levven GSW switch
FCC ID: 2ADH9-GSW IC ID: 12453A-GSW
Blue wires connect to the Line/Hot and Load wires
Les fils bleus se connectent aux lignes de tension et de charge
Cables azules se conectan a las líneas de tensión y de carga
White wire connected to both line and load neutrals
File blanc connecte avec les deux ligne et le chargement neutre
Cable blanco conectado a la dos líneas y a la carga neutra
To Load
Pour chargement
Para cargar
Antenna wire
Fil de l’antenne
Cable de antena
Electrical box
Boîte de jonction
Caja de conjunción
LED status indicator
Indicateur DEL
Indicador DEL
‘Pair’ button
Boutton “Jumelage”
Botón “Acoplar”
From Line Power
Pour ligne d’alimentation
Entrada linea de alimentación
Coupling to mount controller in
knockout hole
Couplage monté dans les trous de prise
Acoplamiento para montar el
controlador de carga en caja eléctrica
Line
Ligne
Línea
Neutral (white)
/ Neutre (blanc) / Neutro (blanco)
Hot (black)
/ Actif (noir) / Fase (negro)
Load
Charge
Carga
Dry contacts (blue)
Contacts secs (bleu)
Contactos secos (biru)
White
Blanc
Blanco
Black
Noir
Negro