7-18
FRX8000 3. 0 User G uide, Rev 02
Figure 7-7 SVC Subscriber Record
[A],[F],[A],[C]
from Main Menu
The parameters displayed by pressing
[1]
or
[2]
are listed in Table 7-4.
When Changes Take Effect
When you add a new Subscriber record, the change will be written to the database as
soon as you enter the final parameter value. When you modify a parameter in an
existing record, the change will be written to the database immediately.
The change will become effective on the trunk as soon as the next call is placed. (The
change will not affect a call in progress.)
Subscriber Parameters
Table 7-4 Subscriber Parameters
Parameter
Valid Values
Default Value
Subscriber Name
0–24 characters
none
Dialup Subscriber
n/a - not yet supported
N
Routi ng Al gori thm
0–2
0
System atic Redirection
Y/N
N
Redir ect on Busy
Y/N
N
Redir ect on O ut of Order
Y/N
N
Bandw. All oc. G roup
1–3
1
1st,2nd,etc. Routing Path
valid node/LP/port
Not used
1st,2nd,etc. Redi rected Sub No.
valid address
Not used
Sub scriber Maintenance
*
Su bscrib er ID
10000100001
A Su bscrib er Name
xsub 1
B Dialup Su bscrib er
N
C Rou tin g A lgorithm
0 Rou nd Rob in
D Sys tematic R ed irection
Y
E Redirect on Bu sy
N
F Redirect on Out of Order
N
G Band w. Allocation Grou p
1
1
Rou tin g Paths
2
Redirection Add ress es
Select:
Summary of Contents for Netlink FRX8000
Page 1: ...User Guide For Release 3 0 09 41 06 150 02 The Complete Networking Solution T M ...
Page 2: ......
Page 14: ......
Page 15: ...Section I Getting Started ...
Page 16: ......
Page 25: ...Section II Configuration ...
Page 26: ......
Page 40: ......
Page 60: ......
Page 80: ......
Page 106: ...7 26 FRX8000 3 0 User Guide Rev 02 ...
Page 148: ...9 30 FRX8000 3 0 User Guide Rev 02 ...
Page 251: ...Section III Operation ...
Page 252: ......
Page 392: ......
Page 397: ...Section IV Appendices ...
Page 398: ......
Page 410: ......
Page 444: ......
Page 448: ......