Configuring LPs and LAN Cards
6-13
Figure 6-6 E1 LP Configuration Record
[A],[C],[C]
from Main Menu
Pressing
[1]
will display the signaling parameters, all of which are listed in
Table 5-5
. Some entries will or will not appear on that screen, depending on values
selected for other parameters.
When Changes Take Effect
When you add a new LP record, the change will be written to the database as soon as
you enter the final parameter value. When you modify an existing record, the change
will be written to the database immediately.
The change will become effective at the LP in one of the following ways:
●
A change to an LP in an ICP, INM, or NMP node is immediately effective when
the database record is changed.
●
A change to LP 0–3 in a DPPM node, can be implemented by performing a
Configuration Update
(
[B], [B], [D], [A]
from the Main Menu) to the node con-
taining the LP.
Be sure to perform the update to a DPPM node before the node
undergoes a re-IPL.
●
A change to LP 4–7 in a DPPM node will take effect at the next IPL of the node
containing the LP.
Lin e Proces sor Maintenance
*
Node I D
10ns n10
*
LP ID
1
A LP Type
4 N7400/7500 T1/E1 LP
B Model Typ e
2 E-1
Coding
3
Framin g
2
E Lin e Service
0
Lin e Build Out
6
Unit Type
0
H Clocking
0
I
Expans ion LP Attached
Y
O Expans ion LP Nu mbers
1
Signalin g Parameters
Select:
Summary of Contents for Netlink FRX8000
Page 1: ...User Guide For Release 3 0 09 41 06 150 02 The Complete Networking Solution T M ...
Page 2: ......
Page 14: ......
Page 15: ...Section I Getting Started ...
Page 16: ......
Page 25: ...Section II Configuration ...
Page 26: ......
Page 40: ......
Page 60: ......
Page 80: ......
Page 106: ...7 26 FRX8000 3 0 User Guide Rev 02 ...
Page 148: ...9 30 FRX8000 3 0 User Guide Rev 02 ...
Page 251: ...Section III Operation ...
Page 252: ......
Page 392: ......
Page 397: ...Section IV Appendices ...
Page 398: ......
Page 410: ......
Page 444: ......
Page 448: ......