21-24
FRX8000 3. 0 User G uide, Rev 02
b50c
– the Trap Action routine (pltrap()) of the PL Finite State
Routine was called.
b701
– the PL Main routine saw an invalid port type.
b702
– the PL Main routine saw an invalid packet layer-to-controller
message.
b703
– the PL Main routine received a message of type NODRSET,
and PLERR was defined.
b704
– the PL Main routine received a message of an unknown type.
b705
– there was an invalid VC ID in the data packet during node-
to-PAD data processing (pl_noddat()).
b706
– there was an invalid VC ID in the response to a Call Request
Data packet during node-to-PAD data processing (pl_noddat()).
b707
– there was an invalid VC ID in the response to a Clear Request
Data packet (REQ_CLEAR) during node-to-PAD data processing
(pl_noddat()).
b708
– there was an invalid VC ID in the response to a Clear Request
Data packet (RSP_CLEAR) during node-to-PAD data processing
(pl_noddat()).
b709
– there was an invalid VC ID in the response to an Interrupt
Request Data packet (REQ_INTRP) during node-to-PAD data
processing (pl_noddat()).
b70a
– there was an invalid VC ID in the response to an Interrupt
Request Data packet (RSP_INTRP) during node-to-PAD data
processing (pl_noddat()).
b70b
– there was an invalid VC ID in the response to an RR during
node-to-PAD data processing (pl_noddat()).
b70c
– there was an invalid VC ID in the response to an RNR during
node-to-PAD data processing (pl_noddat()).
b70d
– there was an invalid VC ID in the response to a Request Reset
Data packet during node-to-PAD data processing (pl_noddat()).
b70d
– there was an invalid VC ID in the response to a Reset
Response Data packet during node-to-PAD data processing
(pl_noddat()).
b70e
– there was an invalid VC ID in the response to an Unknown
Data packet during node-to-PAD data processing (pl_noddat()).
b710
– during the link layer–to–PL message Main routine
(pl_lldata()), the facility was LPDATA and the VC ID was invalid.
b711
– during the link layer–to–PL message Main routine
(pl_lldata()), the facility was LPQDAT and the VC ID was invalid.
b712
– during the link layer–to–PL message Main routine
(pl_lldata()), the facility was LPCA and the VC ID was invalid.
b713
– during the link layer–to–PL message Main routine
(pl_lldata()), the facility was LPSVCD (Terminate QLLC) and the
VC ID was invalid.
Summary of Contents for Netlink FRX8000
Page 1: ...User Guide For Release 3 0 09 41 06 150 02 The Complete Networking Solution T M ...
Page 2: ......
Page 14: ......
Page 15: ...Section I Getting Started ...
Page 16: ......
Page 25: ...Section II Configuration ...
Page 26: ......
Page 40: ......
Page 60: ......
Page 80: ......
Page 106: ...7 26 FRX8000 3 0 User Guide Rev 02 ...
Page 148: ...9 30 FRX8000 3 0 User Guide Rev 02 ...
Page 251: ...Section III Operation ...
Page 252: ......
Page 392: ......
Page 397: ...Section IV Appendices ...
Page 398: ......
Page 410: ......
Page 444: ......
Page 448: ......