D-2
FRX8000 3. 0 User G uide, Rev 02
Reset Causes
An SVC or PVC may be reset when an error occurs during data transmission. The
reset causes transmission to be re-synchronized, and informs the user that some data
might have been lost. The reset cause sent in a Reset packet provides a high-level
indication of why the call was reset.
From DCE
From DTE
Hex.
Dec.
Hex. Dec. Description
00
00
80
128
DTE originated
01
01
81
129
Out of order*
03
03
83
131
Remote procedure error
05
05
85
133
Local procedure error
07
07
87
135
Network congestion
09
09
89
137
Remote DTE operational *
0F
15
8F
143
Network operational *
11
17
91
145
Incompatible destination
1D
29
9D
157
Network out of order *
*
PVC only
Restart Causes
When a port is restarted, all active SVCs and PVCs through the port are cleared. The
restart cause sent in a Restart packet provides a high-level indication of why the port
was restarted.
From DCE
From DTE
Hex.
Dec.
Hex. Dec. Description
00
00
80
128
Local procedure error
03
03
83
131
Network congestion
07
07
87
135
Network operational
7F
127
FF
255
Registration/cancellation confirmed
Summary of Contents for Netlink FRX8000
Page 1: ...User Guide For Release 3 0 09 41 06 150 02 The Complete Networking Solution T M ...
Page 2: ......
Page 14: ......
Page 15: ...Section I Getting Started ...
Page 16: ......
Page 25: ...Section II Configuration ...
Page 26: ......
Page 40: ......
Page 60: ......
Page 80: ......
Page 106: ...7 26 FRX8000 3 0 User Guide Rev 02 ...
Page 148: ...9 30 FRX8000 3 0 User Guide Rev 02 ...
Page 251: ...Section III Operation ...
Page 252: ......
Page 392: ......
Page 397: ...Section IV Appendices ...
Page 398: ......
Page 410: ......
Page 444: ......
Page 448: ......