Alarms
21-31
Meaning:
Self-explanatory.
208.
Cannot access /u/netlink/acnt on node “n”
Severity:
4
Meaning:
Someone has attempted to roll over the Call Accounting file on the
specified node, and the directory acnt does not exist.
Action:
Contact
Cabletron Systems Technical Support
. (See page 21-7.)
209.
Backup call accounting file deleted on node “n”
Severity:
4
Meaning:
A backup file was deleted using the Display/Delete Call Accounting
File operation.
210.
Checksum error in load generation message to this node
Severity:
4
Meaning:
A load generation message has been received and the checksum cal-
culated does not equal the checksum in the message.
215.
PVC connected from LP “n” Port “n” LCN “n” to Node “n” LP “n” Port “n” LCN “n”
Severity:
4
Meaning:
Self-explanatory.
216.
PVC from LP “n” Port “n” LCN “n” to Node “n” LP “n” Port “n” LCN “n” failed
Severity:
4
Meaning:
The attempted connection was not successful, probably because one
end was down.
217.
X25 LP “n” Port “n” is configured but not strapped to generate clocks
Severity:
1
Meaning:
The port (on a AST card) has been configured to generate clock;
however, the LP hardware is configured as physical DTE, which
does not generate clock.
Action:
Depending on whether you want this port to generate clock, change
either the Port record or the LP jumpers.
218.
X25 LP “n” Port “n” is strapped but not configured to generate clocks
Severity:
1
Meaning:
The AST LP hardware is configured as physical DCE, which
generates clock; however, the port has been configured not to
generate clock.
Action:
Depending on whether you want this port to generate clock, change
either the Port record or the LP jumpers.
219.
Illegal TC/Gen Clk Combination
Severity:
1
Summary of Contents for Netlink FRX8000
Page 1: ...User Guide For Release 3 0 09 41 06 150 02 The Complete Networking Solution T M ...
Page 2: ......
Page 14: ......
Page 15: ...Section I Getting Started ...
Page 16: ......
Page 25: ...Section II Configuration ...
Page 26: ......
Page 40: ......
Page 60: ......
Page 80: ......
Page 106: ...7 26 FRX8000 3 0 User Guide Rev 02 ...
Page 148: ...9 30 FRX8000 3 0 User Guide Rev 02 ...
Page 251: ...Section III Operation ...
Page 252: ......
Page 392: ......
Page 397: ...Section IV Appendices ...
Page 398: ......
Page 410: ......
Page 444: ......
Page 448: ......