Alarms
21-23
b001
– the count of Remote SAPs has exceeded the maximum VCs
allowed. (Generated during processing of the IPL parameter packet
(spcfg_iplparm().)
b002
– the PAD type is unknown. (Generated during processing of
spcfg_iplparm().
b003
– the IPL state (iplstate) is not set. (Generated during pro-
cessing of the EX–IPL parameter packet (spcfg_exiplparm().)
b004
– the maximum number of remote controllers has been
exceeded. (Generated during processing of the EX-IPL parameter
packet (spcfg_exiplparm().)
b101
– an unknown message type was received by the controller
task's Entry Point routine (spctlmr()).
b102
– an unknown facility was received from the link layer
(spctl_lnkmsg()).
b403
– when trying to make an M–bit packet (pf_tx_lnkm()), the
buflink parameter of the message was equal to NULL.
b404
– when trying to re–assemble an M–bit packet, the Node Data
packet exceeded the frame size.
b411
– the User Data field of the call packet stored in the VC that
function pf_svcup() is trying to bring up has a length greater than 16.
b412
– when attempting to convert link data to an X.25 packet, the
Remote SAP record (rsapcb) was not set for a PVC and the substate
of the VC Control Block record (vccb) was not set to 1.
b413
– no free VC block was found when attempting to bring up a
VC (pf_svcup()).
b416
– when attempting to convert an X.29 Q–data packet to X.25,
the Remote SAP record (rsapcb) was not set for a PVC and the sub-
state of the VC Control Block record (vccb) was not set to 1.
b501
– no operation took place in the PL Finite State Machine
(PLFSM.C).
b502 & 0xb503
– the plrx_msgdics() function was called to discard a
DCE Receive message. b502 is generated if there is a message to
discard, b503 if no message.
b504 & 0xb505
– the PL Finite State Machine logged a DCE Receive
error (plrx_logerr()). b504 is generated if a message is present, b505
if no message.
b506
– the PL Finite State Machine called the Transmit No Oper-
ation function (pltx_nop()).
b507 & 0xb508
– the pltx_msgdics() function was called to discard a
DTE Receive message. b507 is generated if there is a message to
discard, b508 if no message.
b509 & 0xb50a
– the PL Finite State Machine logged a DTE Transmit
error (pltx_logerr()). b509 is generated if a message is present, b50a
if no message.
b50b
– a DTE Call Request was rejected.
Summary of Contents for Netlink FRX8000
Page 1: ...User Guide For Release 3 0 09 41 06 150 02 The Complete Networking Solution T M ...
Page 2: ......
Page 14: ......
Page 15: ...Section I Getting Started ...
Page 16: ......
Page 25: ...Section II Configuration ...
Page 26: ......
Page 40: ......
Page 60: ......