Configuring Async Pads
13-5
1, PAD Recall Character
allows the user's device to initiate an escape from data transfer state or connection in
progress state in order to send PAD command signals.
Values (can be added) are:
0
= escape is not allowed.
1
= escape will be initiated by
[Ctrl] [P]
(
1/0
),
Data Link Escape
.
32–126
= escape will be initiated by the character defined by this number.
2, Echo
provides for characters received from the user's device to be transmitted back to the
device as well as being interpreted by the PAD.
3, Data Forwarding Char
allows the selection of defined sets of characters received from the user's device to be
recognized by the PAD as an indication to complete the assembly and forward a com-
plete packet sequence as defined in Recommendation X.25. Values (can be added)
are:
0
=
no data forwarding character.
1
=
alphanumeric characters (A-Z, a-z, 0-9).
4
=
ESC, BEL, ENQ, or ACK.
8
=
DEL, CAN, or DC2.
16
=
ETX or EOT.
32
=
HT, LF, VT, or FF.
64
=
all characters in columns 0 & 1 of International Alphabet #5 that are not
included above. (The contents of columns 0 & 1 are equivalent to ASCII
characters NUL through US in the table in Appendix H.)
127
= all characters.
4, Idle Delay
allows selection of an interval between successive characters received from the user's
device, which when exceeded will cause the PAD to terminate assembly of a packet
and forward it as defined in Recommendation X.25. If expiration of the timer occurs
before the forwarding size of the data packet is reached, the PAD forwards the data
packet to the remote DTE.
5, Device Control
allows flow control between the PAD and the user's device. The PAD indicates
whether it is ready to accept characters from the user device by transmitting special
characters that are used to switch DTE transmission on and off.
0
= no use of XON/XOFF.
1
= use XON/XOFF in data transfer.
2
= always use XON/XOFF.
6, PAD Service Signal
provides the user's device with the ability to specify whether or not, and in what
format, PAD service signals are transmitted. Values (can be added) are:
0
= no service signals will be transmitted.
1
= service signals will be transmitted in standard format.
4
= prompt signal will be transmitted in standard format (asterisk).
5
= service and prompt signals will be transmitted in standard format.
Summary of Contents for Netlink FRX8000
Page 1: ...User Guide For Release 3 0 09 41 06 150 02 The Complete Networking Solution T M ...
Page 2: ......
Page 14: ......
Page 15: ...Section I Getting Started ...
Page 16: ......
Page 25: ...Section II Configuration ...
Page 26: ......
Page 40: ......
Page 60: ......
Page 80: ......
Page 106: ...7 26 FRX8000 3 0 User Guide Rev 02 ...
Page 148: ...9 30 FRX8000 3 0 User Guide Rev 02 ...
Page 251: ...Section III Operation ...
Page 252: ......
Page 392: ......
Page 397: ...Section IV Appendices ...
Page 398: ......
Page 410: ......
Page 444: ......
Page 448: ......